[Brocade]SAN Troubleshooting(10)- Hardware Issue

Fabric OS diagnostics is to evaluate the integrity of the system hardware, Diagnostics are invoked in the one of the following ways:
• Automatically during the power-on self test (POST).
# reboot ===> FOS will execute Reboot with POST
# fastboot ===> FOS will Reboot without POST
You can use the diagDisablePost command to disable both POST1 and POST2, and you can re-enable it using the diagEnablePost command. Refer to the Fabric OS Command Reference.
Problems at POST must be troubleshooted through serial console and Output must be captured with Terminal Emulation Software. For further diagnosis.
• Automatically on an individual blade whenever it is installed into a director chassis.
• Manually using Fabric OS CLI commands.

Below are commands to assist you with the troubleshooting.
# switchshow.
Guess we don’t need to explain. This is almost the must check cmd i use for troubleshooting. note that the details displayed for each switch differ on different switch models.

# switchstatusshow
Use the switchStatusShow command to display the overall status of the switch, including its power supplies, fans, and temperature. If the status of any one of these components is either marginal or down, the overall status of the switch is also displayed as marginal or down. If all components have a healthy status, the switch displays a healthy status.
SAN01:FID128:admin> switchstatusshow

Switch Health Report Report time: 06/07/2013 09:41:06 PM

Switch Name: SAN01

IP address: 10.254.208.74

SwitchState: HEALTHY

Duration: 605:25

Power supplies monitor HEALTHY

Temperatures monitor HEALTHY

Fans monitor HEALTHY

WWN servers monitor HEALTHY

CP monitor HEALTHY

Blades monitor HEALTHY

Core Blades monitor HEALTHY

Flash monitor HEALTHY

Marginal ports monitor HEALTHY

Faulty ports monitor HEALTHY

Missing SFPs monitor HEALTHY

All ports are healthy

# hashow
haShow display information about the status of the High Availability feature in the switch. when standby CP report «Failed» which basically mean the standby CP is running, but the background health diagnostic has discovered a problem with the blade. Check the logs to determine the appropriate action. Failover is disabled until the standby CP is repaired. Information about the failing device in the standby CP is displayed.
DCX01:admin> hashow

Local CP (Slot 6, CP0): Active, Cold Recovered
Remote CP (Slot 7, CP1): Standby, Healthy
HA enabled, Heartbeat Up, HA State synchronized
DCX01:admin>

# uptime
The uptime command displays the length of time the system has been in operation, the total cumulative amount of uptime since the system was first powered on, and the load average. The reason for the last switch reboot is also recorded in the system message log.
DCX01:admin> uptime

21:03:33 up 129 days, 18:39, 1 user, load average: 0.08, 0.07, 0.01
DCX01:admin>

# slotshow
slotShow displays the status of all slots in the system.
SAN01:FID128:admin> slotshow

Blade Type ID Status

————————————

1 SW BLADE 77 ENABLED

2 SW BLADE 77 ENABLED
3 UNKNOWN VACANT

4 AP BLADE 75 ENABLED

5 CORE BLADE 52 ENABLED

6 CP BLADE 50 ENABLED

7 CP BLADE 50 ENABLED

8 CORE BLADE 52 ENABLED

9 AP BLADE 75 ENABLED

10 UNKNOWN VACANT

11 SW BLADE 77 ENABLED

12 SW BLADE 77 ENABLED

SAN01:FID128:admin>

# psshow
psshow check the powersupply status
SAN01:FID128:admin> psshow

Power Supply #1 is OK
V10E49, AGC2M49EMVY ,23-0000067-01, B,DELTA,ECD14020006 ,06,AGC2M49E
Power Supply #2 is absent
Power Supply #3 is OK
9EMV0 ,23-0000067-01, B,DELTA,ECD14020006 ,06,AGC2M49EM
Power Supply #4 is absent
SAN01:FID128:admin>

# tempshow
tempshow displays status of temperature sensors
SAN01:FID128:admin> tempshow

Sensor Slot State Centigrade Fahrenheit

ID

========================================================

1 1 Ok 31 87

2 1 Ok 29 84

3 1 Ok 36 96

4 1 Ok 23 73

5 1 Ok 24 75

6 1 Ok 27 80

7 1 Ok 28 82

8 1 Ok 29 84

Output truncated

# fanshow
fanshow display fan status
SAN01:FID128:admin> fanshow

Fan 1 is Ok, speed is 1518 RPM
Fan 2 is Ok, speed is 1518 RPM
Fan 3 is Ok, speed is 1500 RPM
SAN01:FID128:admin>

# sfpshow sfpshow used to check the sfp status on a port.

http://windowspeople.com/Brocade/brocade-san-troubleshooting-10-hardware-issue.html